Normal size
|
As supplied (mm)
|
After recovered (mm)
|
Standard length
(m/spool)
|
(mm)
|
(inch)
|
Inside diameter(Min.)
|
Inside diameter(Max.)
|
Wall thickness(mm)
|
19.1/4.6
|
3/4
|
19.1
|
4.6
|
1.7
|
1.22
|
25.4/7
|
1
|
25.4
|
7.0
|
1.7
|
1.22
|
38.1/9.5
|
11/2
|
38.1
|
9.5
|
1.7
|
1.22
|
50.8/14.0
|
2
|
50.8
|
14.0
|
1.7
|
1.22
|
76.2/20.6
|
3
|
76.2
|
20.6
|
1.7
|
1.22
|
102/26.7
|
4
|
102
|
26.7
|
1.7
|
1.22
|
115/36.8
|
41/2
|
115
|
36.8
|
1.7
|
1.22
|
Special size, cut pieces are available on request.
Property
|
Test Method
|
Typical Data
|
Tensile strength
|
ASTM D 2671
|
16MPa
|
Elongation at break
|
ASTM D 2671
|
800%
|
Tensile strength after aging at 175℃for 168 hrs
|
ASTM D 2671
|
14MPa
|
Elongation after aging at175℃for 168 hrs.
|
ASTM D 2671
|
350%
|
Flammability
|
UL 224 /VW-1
SAE-AMS-DTL-23053/5
|
Pass
|
Heat shock (250℃/ 4 hrs.)
|
ASTM D 2671
|
No cracking
|
Cold bend test (-55℃/ 4 hrs.)
|
ASTM D 2671
|
No cracking
|
Dielectric strength
|
ASTM D 150
|
22KV/mm
|
Volume resistance
|
ASTM D 876
|
1014Ω .cm
|
Copper Corrosion
|
UL 224
|
Pass
|
Water absorption
|
ASTM D 570
|
0.15%
|
Chemical resistance
|
SAE-AMS-DTL-23053/5
|
Pass
|
Longitudinal shrinkage
|
UL 224
|
0±5%
|
Eccentricity
|
UL 224
|
30%
|